How much material for external wall insulation?
Enter the facade area, openings and insulation thickness. The calculator lists every material in the system.
How it is calculated
Net area is the facade minus openings, and boards are counted with 5% waste. Adhesive is used twice: to stick the boards (about 4–5 kg/m²) and for the base coat that the mesh is embedded in (about 4 kg/m²). Fixings are usually 6 per m², more at corners and on tall buildings; their length is the insulation thickness plus about 45 mm embedment.
Graphite EPS insulates 15–20% better than white EPS at the same thickness, and mineral wool is non-combustible and vapour-open but heavier and dearer. On taller residential buildings fire rules may require non-combustible insulation.
Frequently asked questions
What insulation thickness?
In the UK, EWI on solid walls is typically 90–100 mm of EPS or more to meet building regulations for upgrades. In colder climates thicker. Decide with a design or energy assessment.
How many fixings do I need?
Usually 6 per square metre, 8–12 at corners and on high, exposed facades. With mineral wool, fixings are always required.
Are there grants?
Often yes, through national energy efficiency schemes that change over time. Check what is currently available in your country.